Project Background
The client, a coal fired power plant located in a center-east state of India, had a requirement of a water treatment system to recycle the plant’s cooling tower blowdown water. Ultrafiltration was selected as the pretreatment of choice to the Reverse Osmosis (RO) plant. UF was required in the tertiary treatment to provide consistent product water with low silt density index (SDI) to safeguard the downstream RO unit from colloidal fouling.
QUA Solution
The OEM chose QUA’s Q-SEP® hollow fiber UF membranes as the ultrafiltration solution for the project due to its high water quality output compared to other UF membrane suppliers. Q-SEP modules successfully met the plant’s requirements due to their low fouling characteristics, uniform pore size distribution and large surface area which provided high operating efficiency and reliable operation.